914 Log-AnalyseLog file analysis Rotax 914 TCU
? Help
Date21.10.
Start – End14:35:09 – 15:01:37
Recording time26:28 min
Engine run time26:28 min
Sampling rateØ 13 Hz
FormatTLR 4.6 LOG

Rating

  • Warning 14:39:47 5800 up to max. 6200 rpm for max. 1 minute (max. 5,839 1/min, 51.2 s)
    Actions
    1. No action is required.

Time by throttle position

Range%TimeShare
Idle 0–5 7:54 min
29.8 %
Taxi 5–40 4:12 min
15.9 %
Part load 40–90 1:49 min
6.8 %
Continuous power 90–106 5:42 min
21.5 %
TCU transition range 106–112 1.3 s
0.1 %
Take-off power 112–115 6:50 min
25.8 %
Caution: TCU transition range (108–110 %)
The throttle range between 108 % and 110 % must be avoided and passed through quickly when opening and closing the throttle, as unstable boost control and controller oscillations can occur in this range.

Source files

10211435.LOG · 10211440.LOG · 10211445.LOG · 10211450.LOG · 10211455.LOG · 10211501.LOG

Channels

ChannelMinMaxMax. at
Engine speed 1,940 5,839 1/min 14:39:57
Throttle position 115.0 % 14:39:40
Ambient pressure 797 910 mbar 14:39:47
Manifold pressure act. 842 1,426 mbar 14:47:24
Manifold pressure nom. 1,000 1,500 mbar 14:35:09
Servo position 56.3 101.3 % 14:42:31
Airbox temperature 19.9 83.3 °C 14:44:07
Height above start 27 3,546 ft 14:52:43

TCU memory · TCU_Memory_20261021_151614.txt

Engine number444444
Operating hours322:31 h
Boost time0:00 h (0.0 %)
Read out21.10.2026 15:16

Rating

  • Alarm 322:02 h More than 6500 rpm (max. 7,221 1/min, operating time 322:02 h)
    Actions
    1. The whole engine must be inspected, repaired or overhauled in accordance with the BRP-Rotax instructions for continued airworthiness.
    2. Check cylinder differential pressure.
    3. Check that the push-rods are straight.
    4. Check if piston had contact with valve.
    5. Check for out of roundness of valves.
    6. Replace the crankshaft. The crankshaft has to be inspected according to the current Overhaul Manual (OHM) for the respective engine type. Overhaul Manual (OHM) and its appendix is available for any appropriately rated person or entity on request and by following the standards of the original manufacturer.
    7. Inspect all systems for correct functioning.
    8. Detailed inspection of affected engine components.
  • Warning 322:04 h 5800 up to max. 6200 rpm for max. 1 minute (max. 5,996 1/min, operating time 322:04 h)
    Actions
    1. No action is required.
  • Alarm 322:09 h More than 6500 rpm (max. 6,567 1/min, operating time 322:09 h)
    Actions
    1. The whole engine must be inspected, repaired or overhauled in accordance with the BRP-Rotax instructions for continued airworthiness.
    2. Check cylinder differential pressure.
    3. Check that the push-rods are straight.
    4. Check if piston had contact with valve.
    5. Check for out of roundness of valves.
    6. Replace the crankshaft. The crankshaft has to be inspected according to the current Overhaul Manual (OHM) for the respective engine type. Overhaul Manual (OHM) and its appendix is available for any appropriately rated person or entity on request and by following the standards of the original manufacturer.
    7. Inspect all systems for correct functioning.
    8. Detailed inspection of affected engine components.
  • Warning 322:10 h Above 1550 up to 1800 mbar (max. 1,566 mbar, operating time 322:10 h)
    Actions
    1. Caution overboost – please check the turbocharger control: see MMH 912-914 Chapter 76-10-00 TURBOCHARGER CONTROL UNIT (TCU).
  • Warning 322:11 h 5800 up to max. 6200 rpm for max. 1 minute (max. 5,993 1/min, operating time 322:11 h)
    Actions
    1. No action is required.
  • Warning 322:14 h Above 1550 up to 1800 mbar (max. 1,643 mbar, operating time 322:14 h)
    Actions
    1. Caution overboost – please check the turbocharger control: see MMH 912-914 Chapter 76-10-00 TURBOCHARGER CONTROL UNIT (TCU).

Max. operating parameters

ChannelMaximumOper. timeAlertsAlert time
SPEED 7221 rpm 322:02 5 0:00:13
AIRBOX_PRESS. 1643 mbar 322:14 3 0:00:06
AIRBOX_TEMP. 37 °C 322:01 0 0:00:00
BOOST 10.1 %/h 322:15 – –

1 = SPEED 2 = LOAD (Throttle-Pos.) 3 = AIR_PRESSURE 4 = AIRBOX_PRESSURE 5 = AIRBOX_TEMPERATURE 6 = SERVO_POSITION 7 = (reserved) 8 = BOOST_TIME

Alarm records (1-minute maxima)

Oper. time1234568
322:02722195940942371050
322:0459960939941361010
322:096567114937939361040
322:104645115937156636106346
322:1159930936938361010
322:1436001159381643361011123

Interval memory (1-minute maxima)

Oper. time1234568
322:1236000936939361000
322:1336000936939361000
322:1436001159381643361011123
322:154200115937154337103261
322:1624001936939361000
322:1724001936939371000
322:1824001936939371000
322:1924001936939371000
322:2024001936939371000
322:2124001936939371000
322:2224001936939371000
322:2324001936939371000
322:2424001936939371000
322:2524001936939371000
322:2624001936939371000
322:2724001936939371000
322:2824001936939371000
322:2924001936939371000
322:3024001936939371000
322:3124001936939371000